FMC Dialysis Services - Saint Augustine is a medicare approved dialysis facility center in Saint Augustine, Florida and it has 17 dialysis stations. It is located in Saint Johns county at 1680 Osceola Elementary Road Suite B, Saint Augustine, FL, 32084. You can reach out to the office of FMC Dialysis Services - Saint Augustine at (904) 824-6191. This dialysis clinic is managed and/or owned by Fresenius Medical Care. FMC Dialysis Services - Saint Augustine has the following ownership type - Profit. It was first certified by medicare in December, 1982. The medicare id for this facility is 102557 and it accepts patients under medicare ESRD program.
| Name | FMC Dialysis Services - Saint Augustine |
|---|---|
| Location | 1680 Osceola Elementary Road Suite B, Saint Augustine, Florida |
| No. of Dialysis Stations | 17 |
| Medicare ID | 102557 |
| Managed By | Fresenius Medical Care |
| Ownership Type | Profit |
| Late Shifts | Yes |
| 1680 Osceola Elementary Road Suite B, Saint Augustine, Florida, 32084 | |
| (904) 824-6191 | |
| NPI Number | 1386739969 |
| Match | Possible same name, address or phone number |
| Organization Name | National Medical Care, Inc. |
| Doing Business As | Fmc Dialysis Services of St. Augustine |
| Address | 1618 Osceola Elementary Road, St. Augustine, Florida 32884 |
| Phone Number | (904) 824-6191 |
| NPI Number | 1871605626 |
| Match | Possible same name, address or phone number |
| Organization Name | National Medical Care, Inc. |
| Doing Business As | Fmc Dialysis Services St. Augustine |
| Address | 1680 Osceola Elementary Rd Ste B, Saint Augustine, Florida 32084 |
| Phone Number | (904) 824-6191 |
| Dialysis patients with Hemoglobin data | 29 |
| Medicare patients who had average hemoglobin (hgb) less than 10 g/dL | 14 |
For adult patients on hemodialysis, Kt/V should be at least 1.2 and for peritoneal dialysis at least 1.7; that means they are receiving the right amount of dialysis. For pediatric patients, Kt/V should be at least 1.2 on hemodialysis and 1.8 on peritoneal dialysis.
Higher percentages are better.
| Adult patients getting regular hemodialysis at the center | 67 |
| Adult patient months included in Kt/V greater than or equal to 1.2 | 517 |
| Percentage of adult hemodialysis patients with Kt/V greater than or equal to 1.2 | 99 |
An important goal of dialysis is to maintain normal levels of various minerals in the body, such as calcium. This shows the percentage of patients treated at FMC Dialysis Services - Saint Augustine with elevated calcium levels.
| Patients in the hypercalcemia summary | 68 |
| Hypercalcemia patient months | 539 |
| Percentage of adult patients with serum calcium greater than 10.2 mg/dL | 2 |
| Patients in the serum phosphorus summary | 77 |
| Percentage of patients with serum phosphorus less than 3.5 mg/dL | 7 |
| Percentage of patients with serum phosphorus from 3.5 to 4.5 mg/dL | 21 |
| Percentage of patients with serum phosphorus from 4.6 to 5.5 mg/dL | 29 |
| Percentage of patients with serum phosphorus from 5.6 to 7 mg/dL | 28 |
| Percentage of patients with serum phosphorus greater than 7 mg/dL | 15 |
The arteriovenous (AV) fistula is considered the best long-term vascular access for hemodialysis because it allows good blood flow, lasts a long time, and is less likely to get infected or cause blood clots than other types of access. Patients who don't have time to get a permanent vascular access before they start hemodialysis treatments may need to use a venous catheter as a temporary access.
| Patients included in arteriovenous fistula and catheter summaries | 74 |
| Patient months included in arteriovenous fistula and catheter summaries | 555 |
| Percentage of patients getting regular hemodialysis at the center that used an arteriovenous (AV) fistula for their treatment | 58.6 |
| Percentage of patients receiving treatment through a vascular catheter for 90 days or longer | 27 |
The rate of hospitalization shows you whether patients who were being treated regularly at FMC Dialysis Services - Saint Augustine were admitted to the hospital more often (worse than expected), less often (better than expected), or about the same (as expected), compared to similar patients treated at other centers.
| Standardized Hospitalization Ratio (SHR) Period | January, 2024 - December, 2024 |
| Patients in facility's Hospitalization Summary | 68 |
| Hospitalization Rate in facility | 141.4 (As Expected) |
| Hospitalization Rate: Upper Confidence Limit | 232.3 |
| Hospitalization Rate: Lower Confidence Limit | 92 |
The rate of readmission shows you whether patients who were being treated regularly at FMC Dialysis Services - Saint Augustine were readmitted more often (worse than expected), less often (better than expected), or about the same (as expected), compared to similar patients treated at other dialysis centers.
| Standardized Readmission Ratio (SRR) Period | January, 2024 - December, 2024 |
| Readmission Rate in facility | 22.1 (As Expected) |
| Readmission Rate: Upper Confidence Limit | 40 |
| Readmission Rate: Lower Confidence Limit | 9.4 |
Hemodialysis treatment requires direct access to the bloodstream, which can be an opportunity for germs to enter the body and cause infection. This information shows how often patients at FMC Dialysis Services - Saint Augustine get infections in their blood each year compared to the number of infections expected for the center based on the national average.
| Standardized Infection Ratio (SIR) Period | January, 2024 - December, 2024 |
| Infection Ratio in facility | 0.33 (As Expected) |
| SIR: Upper Confidence Limit | 1.07 |
| SIR: Lower Confidence Limit | 0.05 |
Patients with anemia require blood transfusions if their anemia is not managed well by their dialysis center. This information shows whether FMC Dialysis Services - Saint Augustine's rate of transfusions is better than expected, as expected, or worse than expected, compared to other centers that treat similar patients.
| Standardized Transfusion Ratio (STrR) Period | January, 2024 - December, 2024 |
| Patients in facility's Transfusion Summary | 32 |
| Transfusion Rate in facility | 35.5 (As Expected) |
| Transfusion Rate: Upper Confidence Limit | 107.6 |
| Transfusion Rate: Lower Confidence Limit | 15.3 |
The rate of mortality shows you whether patients who were being treated regularly at FMC Dialysis Services - Saint Augustine lived longer than expected (better than expected), did not live as long as expected (worse than expected), or lived as long as expected (as expected), compared to similar patients treated at other facilities.
| Standardized Mortality Ratio (SMR) Period | January, 2021 - December, 2024 |
| Patients in facility's Survival Summary | 259 |
| Mortality Rate in facility | 20.5 (As Expected) |
| Mortality Rate: Upper Confidence Limit | 30.7 |
| Mortality Rate: Lower Confidence Limit | 14.3 |
Davita St Augustine Dialysis Location: 264 Southpark Cir E, Saint Augustine, Florida, 32086 Phone: (904) 808-0445 |
Fresenius Kidney Care St Augustine South Location: 65 Whitehall Dr, Saint Augustine, Florida, 32086 Phone: (904) 797-3600 |